AlcoDigital Advice and Solutions from the
UK's Drug & Alcohol Safety Experts

Call us on 0208 454 7372
ukbreathalysers
Draeger Police 5510
Impressive design. Trustworthy technology.

Home Office Approval Pending  

As entry level model of the successful Draeger Alcotest 6510 the Draeger Alcotest 5510 offers professional users precise and quick breath alcohol analysis in a user-friendly and compact form. Thanks to its wide range of possible configurations, the handheld instrument can be easily adapted to meet different international regulations and guidelines.

Safe and easy to use

Automatic sampling and calibration processes make the instrument easy to use. All measurement functions are controlled via a single key, while menu navigation is by two menu keys. The special waythe mouthpieces are designed means they can be fitted quickly and securely even in poor light conditions.

Rapid ready for use

The very latest in electronics technology ensures that the instrument is ready for use in no time at all.

Quick and precise analysis

The 1/4"-DraegerSensor with its optimized gas dynamics measures specifically alcohol. Even at high alcohol concentrations direct gaspaths, fast pneumatic components and short reaction times of the sensor ensure the measurement result will be displayed quickly.

Low energy consumption

More than 1500 breath alcohol tests can be conducted on just two mignon batteries (AA size).

"Slide'n'click" mouthpiece

The shape of the mouthpiece means you will intuitively fit it correctly. An air outlet which cannot be obstructed prevents any manipulation when the breath sample is given. A spacer on the mouthpiece prevents the test subject's lips from coming into contact with the instrument's housing, and at the same time may be used as a mouthpiece ejector. The individually packaged mouthpieces can be attached to the instrument easily and hygienically.

Practical design

Thanks to its compact dimensions, the Draeger Alcotest 5510 even fits into a shirt pocket. The ergonomic design makes the instrument equally easy to use for right and left-handed people. The separation of the grip area and the mouthpiece automatically ensures a certain distance between the hand of the operator and the mouth of the person to be tested.

Integrated datalogger

The latest 10 measurement results with their respective test numbers are stored in the datalogger. Individual results can be called up from the log by pressing the menu keys.

  • Slide'n'click mouthpiece attachment - Can be fitted for right or left orientation
  • Menu buttons - easy to use menus with 14 different measurement settings
  • Test Memory - last 10 tests stored in memory for easy recall
  • Test Counter - to ensure on-time calibration (every 6 months or 500 tests)
  • Tough Housing - made from shockproof, damp proof
  • LCD Display - 3-colour, to support display and warning messages
  • Single OK button - for simple, intuitive operation
Technical Specification
    

Analytical principle

Electrochemical DraegerSensor in 1/4" technology for alcohol analysis

Measurement precision

Standard deviation ±0.008 mg/L or ±1.7 % of the measurement value. The higher value applies. Drift: typically < 0.6 % of the measurement value/month

READY Time

approx. 3 s

Recovery time

approx. 3 s, at 0 mg/L, depending on ambient temperature

Quick menu

PIN protected: Last 10 tests, Last calibration date, measurement settings, total tests to date

Human interface

All measuring functions can be carried out with one key. Navigation in the menu via 2 menu buttons

Size

approx. 142 mm x 75 mm x 36 mm / 5.6" x 2.9" x 1.4"

Weight

approx. 195 g / 0.5 lbs, incl. batteries

Package Contents

  • Draeger 5510
  • 3 x mouthpieces
  • Wrist strap
  • User's manual
  • Plastic case
  • 2 x 1.5v Duracell Battery

Sometimes able to offer substantial discounts
if you are a member of certain associations
or professions - 
Click here for a Quotation

£ + VAT

- In Stock Now -